ESD Carpet, ESD carpeting Installation and Grounding

UltraTech and Circuit CG conductive carpeting provides an electrically conductive pathway from a person to ground allowing static electricity to be discharged without harming sensitive electronics. In high tech environments (such as networked offices and control towers) static can devastate electronics' causing a variety of "glitches" and blown components required for critical applications. Static control is of such importance in electronic assembly environments, that technicians routinely wear static control shoes or foot grounding devices (in combination with the installed flooring) to provide intimate skin to floor contact and the ultimate in static protection. United Static Control Products Carpeting is Engineered to also control the electrostatic charge generation of rolling equipment such as carts, chairs, test equipment and transport means of subassemblies or completed product. At United Static Control Products we have a variety of ESD flooring materials, however ESD Carpet tiles provide a crisp modular look, can be removed and replaced (when stained or worn) and can be fitted around equipment easier than our anti-static broadloom. When installing remember that static control flooring is an integral component of the clients production reliability, thus the proper installation is important! Utilizing conductive filaments interwoven with a 100% solution dyed nylon and tufted, dense pattern textured loop, this ESD carpeting provides the utmost in overall performance. This superior manufacturing technology provides a carpeting than never requires chemical anti-stat treatments yet provides exceedingly consistent electrical conductivity across the entire surface of the material.
Make sure that the sub-floor and site conditions meet your requirements!
The installation of US carpet tiles shouldn't begin until the work of all other trades (especially overhead trades) has been completed. The installation areas must be clean, fully enclosed, weather-tight and have the permanent HVAC system set at a minimum of 68o F (20o C) for a minimum of 72 hours prior to, during and after installation.

The US Carpet Tiles must be delivered to the installation area and allowed to acclimatize in the same manner. To allow for proper inspection of the substrate, installation of the flooring and final inspection of the install all areas to receive flooring must be adequately lighted. Wood floors should be of double construction with a minimum thickness of 1 inch.

The wood floor must be rigid, free from movement and have at least 18" of well ventilated air space below. Typically, our carpet tiles shouldn't be installed over wooden sub-floors built on sleepers. Contact us if such a install is required.
Our recommended adhesives bond to a variety of substrates!
The subfloor to receive the flooring should be smooth, flat, level, permanently dry, clean and free of all foreign material such as dust, paint, grease, oils, solvents, curing and hardening compounds, sealers, asphalt and old adhesive residue. The concrete must have a minimum compressive strength of 3500 psi. Patch and repair minor cracks and other imperfections with a Portland-base patching compounds.

Do not install floor coverings over gypsum-based leveling or patching compounds. It is essential that calcium chloride moisture tests be taken on all concrete floors regardless of the age or grade level. One test should be conducted for every 1000 sq. ft. of flooring (minimum of 3). The test should be conducted around the perimeter of the room, at columns and where moisture may be evident. The moisture emission from the concrete must not exceed 5.0 lbs per 1000 sq 'ft. in 24 hours (for our conductive liquid adhesive) and 3.5 lbs per 1000 sq/ft for our textile reinforced releasable adhesive tape or our US C2K R Liquid Releasable Adhesive System.

A diagram of the area showing the location and results of each test should be submitted to the Architect, General Contractor or End User. If the test results exceed the limitations, the installation must not proceed until the problem has been corrected.
Insure that the received materials meet your criteria!
Prior to installation of this product insure that all floor covering materials and adhesive have arrived on site, that the dye lots, and part numbers match the clients order and that the materials have arrived in undamaged condition. Don't forget; allow the materials to time acclimatize to the temperature controlled environment of the installation area for at least 72 hours prior to beginning the install.
#
Basic Grounding
1) Concrete
2) Aluminum foil (not attached to ground)
3) Wall,
4) Electrical outlet face plate cover.
United Static Control Carpeting is designed to work in conjunction with one of three types of our conductive adhesives (either our UltraStat Conductive textile reinforced releasable, our ElectraTech 2450 or our  US C2004R Liquid releasable adhesive.  In the case of a non porous surface such as standard VCT, the liquid adhesive must be applied over our conductive primer (contact us for details when covering non porous surfaces) Adhesives are typically applied over a copper foil ground strip or grid (grounding materials supplied at no charge with your order.  The amount of copper foil will vary with the level of protection desired (we group the grounding requirements into three categories; basic, advanced, critical). For extended information on grounding please visit How to Ground ESD carpeting. 
#
Installation Layout is similar to a vinyl or VCT tile install. Installation generally starts in the middle of the area and works it's way out from a carefully placed + pattern with edge of carpet tiles being meticulously placed along chalk lines. Keep in mind, our carpet tiles are DIRECTIONAL and well marked with a arrow on the back of each tile. These arrows MUST all point in the same direction!
Our Adhesives bond to the impossible! Curing just takes a little longer!
As mentioned earlier we have three types of conductive adhesives recommended for use with UltraStatic Control Carpet Tiles. These adhesives are designed to provide a "equiplane of conductivity" between the insulative substrate and the conductive carpeting. Chances are that your client has previously picked the adhesive when ordering the flooring material. When quoting install cost it's always best to ask about their selection. Following are the advantages and specific nuances of each: #

1) US 2000 Releasable Adhesive is a textile reinforced, double stick "tape." Available in conductive and standard. Perfect for installing floors in leased facilities (when you move the floor goes with you). Excellent choice for asbestos laden substrates, raised computer floors and fast track usage (requires no curing time to achieve bond).

This material is supplied in a 39" x 86' rolls. Designed to cover a variety of surfaces including existing well bonded VCT, Linoleum, Cement, Steel, Hardwood, virtually any surface that is smooth, dust and oil free, well bonded and meets the moisture emission requirements of being below 3.5 lbs per 1000 sf (calcium chloride test).

Easy to use, clean, odor free and FAST (saves about 25% in labor over troweled on liquid adhesive). May slightly raise the resistance level of the material you have selected.

2) Releasable Adhesive Application: Grasping inside tube of roll, walk backwards (with light tension on roll), peeling off "run." Align with any adjacent (previous) runs. Note: Although runs can be overlapped it's easiest (for liner removal purposes) to leave a slight 1/16 gap between runs). When comfortable with positioning, lightly broom in place (to remove any excessive bubbles). Remove top liner from sheet, observe carpet lay direction (arrow on carpet tile vinyl backing), place tiles on adhesive surface (starting at inside corner and carefully aligning edges).

Note: Do not compress. Upon completion roll in place with 75# Roller. Floor may be used immediately!
Do Not Compress carpet tiles into place! Slight seams may be evident but blend after vacuuming and usage.

3) US-C2004 R Releasable Conductive Liquid is a releasable, solvent free, water based, one part conductive adhesive system designed specifically for use with our conductive flooring materials. NEW and HIGHLY Recommended. Perfect for raise flooring applications and other installations requiring the flexibility of carpet tile replacement combined with the high bond strength. For more information on this unique patented adhesive please visit: US C2004 Releasable Adhesive.

After installation: If required, carpeting may be cleaned using standard methods and procedures. Vacuuming is all that is typically needed. When required, a "dry" carpet cleaning method is recommended however wet extraction may be used. Do not use a wet extraction method prior to liquid adhesive achieving full cure (72 to 96 hours) and do not over saturate carpeting when wet cleaning. Do not apply any type of carpet protectant (stain or dirt repellants) as this may change the electrical conductivity of material.

  • Dispose installation waste being sure to follow any local and state regulations for the spent materials.
  • If your Client requires a Certification of Electrical Conductivity, contact us for details.



  • Hopefully the electricians and other trades have stayed out of your way during the install ;) Don't hesitate to give us a call if you have questions, comments or if you run into any snags. We're here to help!
    • ESD Flooring
    • |
    • Mats
    • |
    • ESD Floor Care Products
    • |
    • ESD Ionizers
    • |
    • Ultrastat2000.com

    new esd flooring products for 04/05/10

    TERMS CONDITIONS AND YOUR PRIVACY 
    This site is protected by copyright and trademark laws under US and International law.

    United Static Control Products Inc
     

    4878 Lake View Circle

    Colorado City, CO 81019

    United States of America