ESD Carpet Tiles and Broadloom for Static Control

UltraStatic Control Benefits, Physical and  Electrical Specifications

SELECT ESD CARPET TILES AND BROADLOOM

Don't
Don't Zap Your Computer!
your
Electronics

PHYSICAL SPECIFICATION OVERVIEW (see color selections for detailed specifications when selecting your material)

static damageColor Options: 14
static damage Pile Fiber:  Solutia LXI nylon or SD Nylon type 6.
static damage Dye Method: Solution Dye Technology
static damage Surface Texture: Dense tufted, textured loop
static damage Anti-Soil Treatment: Anti-Stain Resist at yarn extrusion. 
static damage Pile Height: high: 6/32", low: 4/32" min 
static damage Machine Gauge: 1/10"
static damage Stitch Count: 11
static damage Tufts: 100
static damage Yarn Construction: Solution Dyed twisted 2/2 ply with continuous conductive fiber in every yarn end
static damage Fiber Weight: Yarn oz./sq. yd, 20 to 24 oz.
static damage Fully Recyclable: Yes
static damage Primary Backing: Woven synthetic
static damage Secondary Backing (broadloom): Action Back, total weight 52 oz/sy min
static damage Secondary Backing (tiles): Fiberglass reinforced static dissipative PVC,  total weight 134 oz/sy min. 
static damage Broadloom Width: 12' 6" and 6' 3"
static damage Tile Sizes: 24" x 24", 18" x 18"
static damage Flammability: Radiant Panel (glue down) ASTM E 648, Class 1 . 4.5 Watts / CM2
static damage Optical Smoke Density: PASSES: ASTM E-662  / NFPA 258 <450 (flaming mode).
static damage Flammability: Methenamine Pill Test, CPSC FF 1-70, self extinguishing
static damage Warranty Classification:  10 year heavy commercial, class III, lifetime warranty on electrical performance.
static damage ADA Compliance: Meets the guidelines as set forth in the Americans with Disabilities Act for minimum static coefficient of friction of 0.060 (ASTM-1028-89 (ASTMC-1028-89) for accessible routes.

ELECTRICAL SPECIFICATIONS

see color selections for detailed specifications when selecting your material)

ANSI EOS ESD S-20.20 Compliant when using approved conductive foot wear system.  Results within recommended range of <3.5E06, <100V

 

static damageElectrical Resistance per EOS / ESD 7.1@ 100 Volts: Average on concrete substrate.

  • RTG: 5.7E04 to  1.0E06

  • PTP: 1.2E04 to 1.0E06

static damageDOD HDBK263A, Section 40.12: Meets recommended guidelines for sensitive ESD Devices, Class 1

 

static damageCharge Decay: Conditioning: 50% RH +/-2%@23°C+/-1° for 24 hours, Tested @: 50% RH +/-2%@23°C+/-1°C:
  • <0.02 seconds, (results = time to decay to 10% of initial charge)