Click Here to Visit our Original Site
  • Home
  • How to Order
  • Contact
  • Site map
  • Privacy
719-676-3928 Live Chat! Email Us

ESD Ionizers and Static Control Ionization

Powerful performance, outstanding reliability!

OUR PRODUCTS

ESD Concrete Sealer

ESD Vinyl Tile

ESD Carpet Tile

ESD Sheet Floors

ESD Epoxy Floor Paint

ESD Wax, ETC

ESD Matting

ESD Constant Monitors

Wrist & Heel Straps

ESD Ionizers

ESD Test Equipment

ESD Smocks

PURCHASE ON LINE

Shopping Cart!

 

 

VIEW THIS SITE IN

Spanish

 

0
[Back] Home / ESD Ionizers / ESD Ionizers / ElectraFlow® SL-004

ElectraFlow® SL-004

Four Fan Overhead ESD Ionizer for Static Control

Four Fan Overhead ESD Ionizer for Static Control
Four Fan Overhead ESD Ionizer for Static Control
SL-1104 - $640

BUY ONLINE!

Free Shipping
  • Outstanding quality, ISO manufactured to stringent specifications
  • Powerful yet balanced, robust performance, very low maintenance
  • Certificate of compliance provided at no charge with each unit
  • +/- 5 volt steady state offset voltage balance provides optimum performance
  • Built in emitter cleaning brushes (point cleaner knob), easy to keep clean
  • Self adjusting circuitry, factory calibrated, further calibration typically not required
  • Easily controllable high output multi speed fans
  • Mounting brackets included at no charge with each ionizer
  • CE Certified, One Year Warranty and built to last a lifetime
  • The SL-1104 meets or exceeds the recommended technical requirements of ANSI/ESD S 20.20- 2007 tested in accordance with STM3.1
Our SL-1104 4 fan overhead esd ionizer provides a massive (440 CFM) yet highly balanced (+/- 5 V) ionic output making it the perfect selection for large static control esd workbenches, static free work areas, production lines, packaging and more. Unlike many ionizers that require contaminant free air and continual maintenance, the SL-1104's steady-state, self balancing circuitry continuously adjusts to compensate for emitter point wear, line voltage fluctuations, variations in air particulate and velocity keeping maintenance to a minimum and performance at a maximum. Used by major companies world wide, the SL-1104 features ultimate ionic output (but no overhead lighting like our SL-003). It's quiet, with fully adjustable (0 to 100%) airflow, long life tungsten emitters (typical life span three years and easy to replace) and a casing manufactured of a light weight aluminum alloy with a static dissipative powder coating (meticulous high tech finish).

Specifications

Line Voltage110V/60Hz standard, 220V/50Hz optional
Current DrawMax 1.66 Amp (fan high)/ Min 0.83 Amp (fan low)
Operating Temperature0~50oc (32o F to 122o F)
Weight26.5 pounds (12 kg)
Finish & CasingPowder coated aluminum alloy
Size46.5" (L) x 6.10" (W) x 4.33" (H) Inches
Air volume outputFan speed low: 180 CFM/ Fan speed high: 440 CFM
Note: Flow amount equals sum of four fan operation.
Air coverage28" x 54" (inches)
Recommended distance from work surface24" to 54" (inches)

Decay Test Results

Testing Conditions Operating Voltage: 110V/220V, Testing Voltage: 1kV to 100V, Temperature: 22°c
Distance300mm600mm900mm1200mm
Left 0.7 2.1 4.9 6.1
Center 0.6 1.9 4.2 5.7
Right 0.7 2.0 4.7 6.0

Installation Overview

Note Following are overviews, please see the manual included with product for full details.
The SL-1104 is an overhead unit designed to provide ideal coverage for control of electrostatics. Note: Do not insert objects into air intake or outlet grille and do not operate the SL-1104 in inflammable or explosive environments. The SL-1104 ionizer should be affixed 24 to 54 inches above the work surface with center targeted directly over work area. Avoid drafty locations such as that caused by air conditioning, heater outlets, etc.

Attachment to overhead supports Mounting to ceilings and shelves; S hooks and chains may be used for mounting the ionizer to structurally sound ceilings or wire shelves. Chains and mounting hardware should have a minimum safe working load of at least 50 pounds. When mounting the unit to ceilings it's important to check state and local codes to insure compliance. The units are typically hung in the same fashion as overhead light fixtures (independently attached to overhead building superstructure). Attaching to suspended ceilings only are typically not compliant with local codes. Mounting to workbench overhead supports; The SL-1104 may be mounted to work bench overhead shelves and beams using the adjustable mounting brackets included with your order.

Electrical Requirements

The SL-1104 requires 110VAC /60Hz (standard) or 220VAC / 50Hz (optional) power. These units must be grounded. Each unit is supplied with standard US 3 prong male grounded power plug (standard). Do not modify the plug or use an ungrounded 3 prong receptacle. If an extension cord is required use heavy gauge fully grounded cords only

Operating Procedure

Activate the SL-1104 overhead ionizing blower by turning fan speed knob clockwise. The ionization indicator will illuminate and indicate the presence of ionized air. Airflow speed can easily be adjusted from 0% to 100% output utilizing the fan speed knob. The time required to neutralize electrostatic potential is dependant on distance of ionizer to work surface and speed of fans. When used in electronic assembly the ionized air stream should cover as much of the working area as possible. The constant flow of ionized air prevents items from developing an electrostatic potential and neutralizes electrostatic charges present on objects introduced to the airflow.

Routine Maintenance Overview

Clean emitters as needed (usually every two weeks in heavy service). To clean ion emitter points press and turn point cleaner knob (located at each air outlet) clockwise approximately one turn and release. Clean air inlet and outlets as needed with a soft brush or vacuum. Periodically test ion output as indicated by your internal esd program or ANSI/ESD S 20.20-2007, TR53, Air Ionizer Compliance Verification (discharge time and offset voltage). Offset voltages of >+/- 50 volts or decay times that exceed user defined specifications (typically <1.1 sec @ 60%rH and 68 deg F. with ionizer positioned 24" from work surface) may indicate the need for replacement of emitters. Normal emitter life is 3 years, replacement emitters are easy to install and available from United Static Control Products.
  • ESD Flooring
  • |
  • Mats
  • |
  • ESD Floor Care Products
  • |
  • ESD Ionizers
  • |
  • Ultrastat2000.com

new esd flooring products for 04/05/10

TERMS CONDITIONS AND YOUR PRIVACY 
This site is protected by copyright and trademark laws under US and International law.

United Static Control Products Inc
 

4878 Lake View Circle

Colorado City, CO 81019

United States of America